Reference [Other Functions]
Switching the level meter 
Hard disk maintenance 
display type 
This section describes how to test and restore the integrity of 
The level meter below the display can indicate the level of 
data on the internal hard disk, and how to perform other hard 
the signal before passing through the level controls/faders 
disk maintenance functions. 
(pre fader) or after passing through the level controls/faders 
(post fader). You can change the setting as follows. 
Basic maintenance procedure 
1.
From the main screen, press the [UTILITY] key in 
The procedure for hard disk maintenance is the same for 
the display section. 
most operations. The basic procedure is as follows. 
The utility menu appears. 
1.
Turn power to the MRS 802 off. While holding 
down the [CLEAR] key, turn power on again. 
UTILITY
UTILITY
TR EDIT
TR EDIT
The MRS 802 starts up in  ROM utility mode  which serves 
for performing special functions. 
2.
Use the cursor left/right keys to bring up the 
indication  UTILITY SYSTEM  on the display, and 
ROM UTY
ROM UTY
press the [ENTER] key. 
MRS 802
MRS 802
The system utility menu for making various system settings 
appears. 
2.
Press the [MARK] key in the control section. 
The indication  ExtFunc Select  appears on the display. 
SYSTEM
SYSTEM
FOOT SW
FOOT SW
ExtFunc
ExtFunc
3.
Use the cursor left/right keys to bring up the 
indication  SYSTEM LVL MET  on the display, and 
3.
Use the cursor left/right keys to select the desired 
press the [ENTER] key. 
command. 
The current level meter setting will be displayed. 
The following commands are available. 
  ScanDisk 
LVL MET
LVL MET
Test and repair the integrity of data stored on the internal 
POST
POST
hard disk. 
The setting has the following meaning. 
  Init Fac (Factory Initialize) 
  POST 
Restore files and data necessary for operation such as the 
The meters show the level of the signal after passing through 
system files. Data created by the user will not be erased. 
the [REC LEVEL] controls/faders (default setting). 
  Init ALL (All Initialize) 
  PRE 
Format the internal hard disk and then restore files and data 
The meters show the level of the signal before passing 
necessary for operation such as the system files. All existing 
through the [REC LEVEL] controls/faders. 
projects on the hard disk will be erased. 
4.
Turn the dial to change the setting. 
4.
Press the [ENTER] key to execute the command. 
Subsequent display indications and operation steps differ for 
5.
To return to the main screen, press the [EXIT] key 
the individual commands. See the respective section below. 
several times. 
ZOOM MRS 802
137






footer




 

 

 

 

 Home | About Us | Network | Services | Support | FAQ | Control Panel | Order Online | Sitemap | Contact

ireland web hosting

 

Our partners: PHP: Hypertext Preprocessor Cheap Web Hosting JSP Web Hosting Ontario Web Hosting  Jsp Web Hosting

Cheapest Web Hosting Java Hosting Cheapest Hosting

Visionwebhosting.net Business web hosting division of Vision Web Hosting Inc.. All rights reserved